蓝亚实验室 - 测试、检验与认证服务

博客

eCall Data Validation: Are You Transmitting More Than the Minimum Required Information?

Contact: [email protected] | WhatsApp: +86 17663606879


In an emergency, an eCall system must transmit the information needed to support an emergency response.

But how can automotive manufacturers ensure that the data transmitted by an in-vehicle emergency system remains within the defined scope?

For OEMs, Tier 1 suppliers and eCall system developers, data content and transmission logic deserve careful attention during system validation.

1. Regulatory Background: Regulation (EU) 2015/758

Regulation (EU) 2015/758 establishes type-approval requirements for the deployment of the 112-based eCall in-vehicle system.

Article 6 addresses privacy and data protection.

In particular, Article 6(8) states that the Minimum Set of Data (MSD) sent by the 112-based eCall system should contain only the minimum information referred to in the cited EN 15722:2011 standard, and that no additional data should be transmitted by the 112-based eCall system.

The same provision also addresses the storage and permanent deletion of MSD data.

2. What Should Automotive Developers Pay Attention To?

A. Data Content

The MSD is not intended to become a general-purpose vehicle data package.

Development teams should review:

  • The data fields included in the MSD

  • The source of each data item

  • The mapping between vehicle information and the applicable MSD definition

  • Whether any additional information is being included in the 112-based eCall transmission

B. Data Transmission

The transmission process should be reviewed against the intended emergency-call workflow.

Relevant project checks may include:

  • Whether transmission is triggered under the intended emergency conditions

  • Whether the correct MSD content is generated

  • Whether the transmitted data matches the prepared data

  • Whether unexpected or additional fields appear in the transmission

C. Data Storage and Deletion

Article 6 also addresses data retention and deletion.

Engineering teams should review:

  • How MSD information is temporarily stored

  • How data is removed when it is no longer required

  • Whether the system supports full and permanent deletion

  • Whether data is accessible outside the 112-based eCall system before an eCall is triggered

3. What About TPS eCall and Other Connected Services?

An important distinction is necessary.

The requirements discussed above concern the 112-based eCall in-vehicle system. They should not automatically be interpreted as a blanket prohibition on all data processing by every connected vehicle service.

Article 6 separately addresses TPS eCall and other added-value services.

It also requires appropriate separation between the 112-based eCall system and additional systems providing TPS eCall or added-value services, including restrictions on the exchange of personal data between them.

This distinction should be reflected in the system architecture and compliance assessment.

4. A Practical eCall Validation Checklist

For project teams, the following checks can help organise validation activities:

Data definition

  • Review the applicable MSD specification and version.

  • Map each transmitted data field to its technical definition.

  • Identify any additional fields in the transmission structure.

Transmission behaviour

  • Verify the data generated during the intended emergency-call scenario.

  • Compare the prepared MSD with the transmitted content.

  • Review abnormal and interrupted transmission scenarios.

Data protection

  • Review data access before eCall activation.

  • Examine data storage and deletion mechanisms.

  • Assess separation between the 112-based eCall and additional service systems.

These are project validation recommendations. The specific test procedures should be determined using the applicable technical and type-approval requirements.

5. An Important Note on Standard References

The consolidated text supplied for this review is dated 9 May 2024.

It is important to distinguish Article 6(8), which refers to EN 15722:2011, from Article 5(8)(d), which lists EN 15722:2020 in its technical standards section.

Project teams should verify the applicable legal text, standard edition and relevant implementing requirements before finalising a compliance assessment.

Final Thoughts

eCall compliance is not only about establishing an emergency call. The accuracy of data content, transmission behaviour, storage and privacy protection are also important parts of the overall system assessment.

At Blue Asia, we support automotive electronics projects through EMC testing, wireless certification and automotive-related testing and compliance services.

For teams developing in-vehicle communication and connected automotive systems, we welcome discussions on potential testing and certification cooperation.


Contact: [email protected] | WhatsApp: +86 17663606879


SHARE

本文作者

Olivia

CNAS 认可实验室工程师,分享射频、EMC 与全球认证一线笔记。

获取报价

在线服务

[email protected] 4000259520 8613534225140
首页 热线电话 手机号码 电子邮箱
回到顶部
联系我们
我们使用 Cookie 以提升您的在线体验。继续浏览本网站,即表示您同意我们使用 Cookie。

Cookies

关于 Cookie

Cookie 是访问网站时存储在您设备上的小型文本文件。蓝亚实验室使用 Cookie 记住您的语言偏好、保障表单安全,并了解访客如何使用我们的页面。

我们使用的 Cookie

必要 Cookie——语言选择与表单安全,无法禁用。
性能 Cookie——用于改进网站的匿名访问统计。

我们不使用广告或追踪 Cookie。您可以随时在浏览器设置中屏蔽或删除 Cookie,但部分功能可能受影响。

联系我们

对本政策有疑问?请发送邮件至 [email protected]。